In order to assure that liquid refrigerant does not return to the compressor during the running cycle, attention must be given to maintaining proper superheat at the compressor suction inlet. Emerson recommends a minimum of 20F (11C) superheat, measured on the suction line 6 inches (152mm) from the suction valve, to prevent liquid refrigerant .... Dell 4 amber 1 white

The symptoms are low suction, normal subcooling, and high superheat when a TXV fails "shut," but there are some other issues to watch for that can actually result in overfeeding the coil. Schrader in the Port. The external equalizer tube on a TXV connects to the suction line at the evaporator outlet and provides a closing force to the valve.3. Low superheat adjustment 4. Bulb installation a. Poor thermal contact b. Warm location 5. Wrong thermostatic charge 6. Bad Compressor - low capacity 7. Moisture, dirt, wax 8. Incorrectly located external equalizer h h S t L w S n e p S e POSSIBLE CAUSES 1. Moisture, dirt, wax 2. Undersized valve 3. High superheat adjustment 4. Gas charge ...The unit cooled the house down to 70 it's probably 85 outside. These are my readings 296psi high side, 95.8 lstat, 93.6 line temp, 2.3 subcool. 140.6psi low side, 50.1 vstat, 51.3 line temp, 1.2 superheat. 20degree delta tee across the return and supply.What causes low superheat and high subcooling? Because these readings are normal, the low suction pressure is caused by insufficient heat getting to the evaporator rather than low refrigerant. CAUSE #2: A faulty, plugged-in, or undersized metering device is to blame. As refrigerant is added to TXV systems with high superheat, double-check the ...High Subcool Low Superheat. Hi I own two wonderful Trane wethertron heat pumps"8 seer". 85 degree day 115 condensing temp. Low side was 65 psig High side 240 psig. 6.5 superheat and 25 degree subcooling. My first assumption was overcharge due to poor winter performance energizing aux heat strips a lot. Right now in cooling I have a 17 …October 10, 2000. Different types of metering devices have different ways of charging. An air conditioning unit with a thermostatic expansion valve (TXV) is charged to the subcooling of the liquid line leaving the condenser because the superheat is fixed. The superheat is fixed at 8°F to 12°F in most residential air conditioning systems.162. 25. I know that having both high superheat and low subcooling on an Air-Conditioner (A/C) is a strong indication that an air-conditioner does not have enough refrigerant. When the charge on an A/C is low, there is less refrigerant that enters the evaporator. When there is a lower amount of refrigerant entering the evaporator, it takes …Low subcooling and high superheat are both conditions that can occur in a refrigeration system and indicate a problem with the system's balance. Low subcooling means that there is an insufficient amount of refrigerant in the condenser, which is the part of the system where the refrigerant releases the heat it has absorbed from the evaporator. In this podcast episode, we ONCE AGAIN talk about superheat and subcooling. This episode is a recap to help people who struggle with the concept. You get superheat when you have 100% vapor, and you have subcooling when you have 100% liquid; any liquid-vapor mixtures are in a saturated state. We usually measure superheat outside at the suction ... What does low superheat mean? ... Overcharge. What does low subcool mean. Undercharge. If you wire up to 24 V transformers how do you wire them? In parallel with each other, phasing has to match. If you measure humidity in the air, how do you do that? Wet bulb temperature. Formula to remember.low-pressure indoor wet-bulb suction-line condenser evaporator and Low-pressure gauge reads 67 psi, which corresponds to 39°F evaporating temperature. Superheat is 52° - 39° = 13°F. Superheat test: Superheat is the heat added to the evaporating vapor to ensure that no liquid enters the compressor. For a ˚xed-ori˚ce system this value ...4. When ambient air temp (Outside air temp) is 75-85 degrees the superheat should be 12-15 degrees, if the ambient temperature is 85 degrees or over the superheat should be 8-12 degrees. 5. If superheat is low then flooding the evaporator. Note: Do not adjust charge yet. 6. If superheat is high then starving the evaporator. Note: Do not adjust ...Over-feeding txv would cause low subcooling and low superheat - but it's possible there are multiple problems covering up for each-other or totally throwing off the readings. My theory is valid I believe, considering a few weeks ago it was checked in mild weather and had more normal suction pressure.1. a) Most walk-in coolers and freezers use a TX valve to regulate the flow of refrigerant into the evaporator. If the superheat is low the TX valve will allow refrigerant to flow into the evaporator at a rate that exceeds the capacity of the evaporator and as a result liquid will enter the suction line.A high superheat is an indication of either a low refrigerant charge or a liquid line restriction problem. To tell the difference between the two problems, we look at subcooling. A system with a low refrigerant charge will have a low subcooling. A system with a liquid line restriction will have a normal to high subcooling.When calculating superheat, we use the "dew point." We use the "bubble point when calculating subcooling. The saturation temperature is the range of temperatures between those two points; a temperature could be "interpreted" as negative superheat or subcooling when it is actually just in the saturated range. In air conditioning, the ...Tripping High Pressure Switch. High Liquid Pressure/ Low Subcooling. Unit Running in Cool Mode. High Liquid Pressure / High Subcooling. Compressor Runs but Does Not Pump. High Suction Pressure / Low Liquid Pressure. Compressor Tries to Start But Does Not. Low Suction/ Low Superheat (fixed metering device)Superheat is measured as the difference between the actual temperature of refrigerant vapor at a certain point and the saturation temperature of the refrigerant. It's not complicated, but for a beginning tech, it might be.". Superheat may be so complicated just because of the term "heat," Tomczyk said. "Because something can be minus ...The less refrigerant flowing through the system, the less the suction line of the system will cool off. You can have a warm suction line (high superheat) due to low charge, a restriction, or high airflow. This indicator is one of many that you need to consider when diagnosing refrigerant problems. Looking at the pinched hose example, we can see ...what is the benefit of having a fixed orifice over a TXV? 1) they're cheaper and 2) easier to replace. can we have an orifice and a heat pump true or false. true. what is superheat? the amount of heat added to a gas above its saturation point. what is subcool? the heat removed from a liquid below its saturation point.Superheat determines by how many degrees of temperature refrigerant vapor increases in the system. We are usually looking for 7°F to 15°F superheat.Too low superheat (below 2°F) = Risk of flooding the compressor, too high superheat (above 15°F) = Risk of overheating the compressor.More about that in our general superheat and subcooling article here.On traditional HVAC/R systems, which utilize mechanical metering devices such as a TXV or cap tube, the superheat heating will vary between 8 °F to 20 °F. On newer systems, which use electronic expansion valves and solid state controllers, it is possible to see the superheat setting as low as 5 °F to 10 °F.Superheat= 6 (Seemed Low) I was taught that on an older system to expect the unit to condense about 30 degrees hotter than the outside temperature. So 78 degrees plus 30 degrees = 108 degrees or approx. a discharge pressure closer to 225 psi. ... Subcooling = 29 Low Side Pressure= 65 Low Side Line Temp = 57 Low Side Saturation Temp (from PTC ...However, this time you consider the three main causes of low suction pressure and check superheat and subcooling to make the correct diagnosis. CAUSE #1: Insufficient heat getting to the evaporator. This can be caused by low airflow (e.g., dirty filter, slipping belt, undersized or restricted ductwork, dust and dirt buildup on blower wheel) or ...I’ll get some soapy water and check the braze joints. From the Goodman manual for that model. Outside drybulb 95F inside drybulb 80F. Hi pressure = 335 Psig, Lo pressure 130 Psig. Which is 20-30 psi off on both. But I was under the assumption if it where low on 410a there would be high superheat and high subcooling.One sign of low subcooling is high suction pressure in your HVAC system. When there’s not enough subcooling, the refrigerant pressure in the system can become elevated, which can lead to poor cooling performance and potential damage to your system. Low discharge pressure. Low discharge pressure is another sign of low subcooling.Actual Box Temp. Cond Temp should be ±10∘F Actual Cond Temp = Cond Subcooling = (2) Actual Evap Temp = (1) Evap Temp should be TEV 80∘. Question: (7) Symptoms Service Problem 7-4 Cond. Temp: High Low Normal - Walk-in FREEZER Subcooling : High Low Normal - R404A Evap. Temp : High Low Normal - TEV Superheat : High Low Normal (9) Repair ...Liquid line temp 101 degrees and the suction was 49 degrees. The low subcooling and low suction pressure indicate low airflow. The somewhat low deltaT seems to contradict that. Could be a significant amount of air bypassing the coil based on your report, which would account for all of the numbers that you posted.October 10, 2000. Different types of metering devices have different ways of charging. An air conditioning unit with a thermostatic expansion valve (TXV) is charged to the subcooling of the liquid line leaving the condenser because the superheat is fixed. The superheat is fixed at 8°F to 12°F in most residential air conditioning systems.Dynaboard built a low-code web application development tool to bring together product managers, designers and developers in a single tool. Dynaboard founder Alex Kern has been prog...the low side. o Low superheat with high subcooling indicates an overcharge. Too much liquid on both sides. o High superheat with low condenser subcooling indicates an undercharge. Not enough liquid on either side. Low side superheat and condenser subcooling simply tell us where the refrigerant is located.Refrigerant undercharge: When there is not enough refrigerant in the system, it can result in low suction pressure, low head pressure, high superheat, and high sub-cool. Restriction in the refrigerant line: A physical blockage in the refrigerant line can cause reduced suction and head pressure, as well as imbalances in the system.High SH Low SC Low SH High SC Superheat Subcool Charge Good Good Good High Low Low Low High Over-Charge High High Restricted Low Low Over-feeding Only evaluate charge after the airflow has been confirmed to be accurate and coils are confirmed to be clean. College of HVAC Education . Title: Microsoft Word - Thumb Chart complete.doc ...the low side. o Low superheat with high subcooling indicates an overcharge. Too much liquid on both sides. o High superheat with low condenser subcooling indicates an undercharge. Not enough liquid on either side. Low side superheat and condenser subcooling simply tell us where the refrigerant is located.In this HVAC Training Video, I Explain Why we need to Measure the Refrigerant Charge with Subcooling when a TXV Metering Device is used. I Explain why the To...Superheat = Current Temperature - Boiling Point. Superheat is measured by its temperature above its boiling point. If a refrigerant vapor boiling point is 140 degrees, for example, then anything about that pressure would be too high for that specific refrigerant. To calculate the measurement of subcooling, the formula is: Subcooling = Boiling ...May 13, 2016 ... ... Superheat needed. You then compare this Actual Superheat to the Superheat needed in order to figure out if you are Low on Refrigerant or ...TXV or cap tube, the superheat heating will vary between 8 °F to 20 °F. On newer systems, which use electronic expansion valves and solid state controllers, it is possible to see the superheat set-ting as low as 5 °F to 10 °F. A low or zero superheat read-ing indicates that the refrigerant did not pick up enough heat inLow airflow (or more generally, low heat load), will give you low Vsat and low superheat. In fact, low heat load is the only way to get low Vsat and low superheat at the same time. If you have low Vsat and low SH, then you absolutely, 100%, without any shadow of a doubt, have low heat load inside. It is literally impossible for anything else to ...This is an intermediate discussion on superheat and subcooling in which I go over why superheat and subcool are important. About Lianna; Posts; Contact Me; Home; Superheat and Subcooling Part II. I wrote about the basics of superheat and subcool, which you can read here. ... Low superheat (aka a "flooded evaporator") can be caused by many ...proper low- and high-side pressures, set superheat and subcooling temperatures, and to set pressure controls. The tempera-ture glide of a blend will determine how the PT chart will look. Therefore, a quick review of tem-perature glide from last month's arti-cle is necessary: • As a portion of a refrigerant blend works its way down the lengthFeb 5, 2017 ... ... it means to have high superheated, low superheat high subcooling and low subcooling. I explain the other things that affect the superheat and ...4. Low Subcooling Caused Poor Compression (Potential Compressor Problem) 1. Low Refrigerant Charge (Low Subcooling) Or High Refrigerant Charge (High Subcooling) The most common cause for non-normal subcooling is a wrong refrigerant charge. If the system is overcharged (too much freon), we will get high subcooling.The unit cooled the house down to 70 it’s probably 85 outside. These are my readings 296psi high side, 95.8 lstat, 93.6 line temp, 2.3 subcool. 140.6psi low side, 50.1 vstat, 51.3 line temp, 1.2 superheat. 20degree delta tee across the return and supply.Aug 12, 2019 · On traditional HVAC/R systems, which utilize mechanical metering devices such as a TXV or cap tube, the superheat heating will vary between 8 °F to 20 °F. On newer systems, which use electronic expansion valves and solid state controllers, it is possible to see the superheat setting as low as 5 °F to 10 °F. Many manufacturers recommend a subcooling range of 10° – 15°F, but always refer to manufacturer instructions to be sure. Just as there are two kinds of superheat, there are also two kinds of subcooling. They are condenser subcooling and total subcooling. We usually measure subcooling at the liquid line service valve.subcooling somewhere around 12-15 degrees F. Suction Pressure around 21-22 psia = -15 to -14 deg.f. Suction line temp. leaving evap. = -12 to -2 deg. F. (The temperature swing is -12 to -2) It stays quite stable. Isn't radical with the temp. swing. box temp. -5. It's an empty walk in box about 7 x 10 foot square.Superheat is measured as the difference between the actual temperature of refrigerant vapor at a certain point and the saturation temperature of the refrigerant. It’s not complicated, but for a beginning tech, it might be.”. Superheat may be so complicated just because of the term “heat,” Tomczyk said. “Because something can be minus ...Calculating superheat can tell us how far liquid Freon is traveling through an evaporator coil. If superheat is too high, there's less liquid and more gas in the coil. This can cause overheating. If superheat is too low, more liquid and less gas are in the coil. This can cause flooding and damage in the compressor.Oct 29, 2022 · The increase in temperature above saturation is described as the refrigerant’s superheat value. For example, at 18.42 psig, R-134a has a saturation temperature of 20°F. If its measured temperature is 30°F, the refrigerant is said to be superheated by 10°F. One useful area to measure the refrigerant’s superheated value is at the exit of ... GENERAL. Through job site applications it has been discovered that specific YVAA chiller circuits may exhibit low discharge superheat faults due to the quantity of oil in the oil separator. Engineering testing has determined that to correct the nuisance superheat trips it is recommended to reduce the oil charge in these specific circuits.Too low is when the liquid stops moving and becomes solid. But seriously, the lower the liquid temp entering the txv, The less energy is wasted to bring that liquid temp down to the evaporating temp. Eg: 55c entering txv down to -10c as it exits txv. Vs 35c to -10c. Or 45c down to -30c vs 25c down to to-25c.Subcooling is when the liquid refrigerant in your is colder than the minimum temperature required to keep it from boiling. This can happen when the system is first turned on, or if there's a problem with the system. When this happens, the liquid refrigerant can change from a liquid to a gas phase, which can cause problems with the HVAC system.If I have my theroy right I have a low superheat of 10 and a high subcooling of 21. Ambiant temp outside is 81 and all temps are in F. 19-07-2011, 03:16 AM #40.Low head pressure due to low ambient conditions can impact the ability of the valve to do its job. Check the superheat at the end of the evaporator and ensure that it is maintaining 6-14°F at the evaporator outlet. If superheat is lower than 6°F, it could be overfeeding; if well above 14°F, then it’s a failed closed (underfeeding) valve.Low Water Flow-Verify design flow; Low Refrigerant charge: Verify Subcooling (15-20 F) and EXV 40-50% open at full load, 12 F superheat; Ratio= EXV % flow command / Superheat Control Compressor Flow estimate > 1.6; Incorrect Setting of Low refrigerant Temp Cutout (IOM). It should be set for type and percent (%) of glycol concentrationLow Superheat = Flooded Evaporator Sub Cooling is telling you what is going on in the condenser. High Sub Cooling = Flooded Condenser Low Sub Cooling = Starved Condenser To Determine Delta T (Temperature difference across the coil): 1. While unit is running take the temperature of the air in the supply plenum near the coil (approx 12Low Subcooling: This may indicate undercharging of refrigerant or a refrigerant leak. High Subcooling: This could suggest refrigerant overcharging or a blockage in the liquid line. Low Superheat: Often a sign of overcharging or a failing metering device. High Superheat: Typically indicates undercharging, a dirty evaporator, or airflow problems.162. 25. I know that having both high superheat and low subcooling on an Air-Conditioner (A/C) is a strong indication that an air-conditioner does not have enough refrigerant. When the charge on an A/C is low, there is less refrigerant that enters the evaporator. When there is a lower amount of refrigerant entering the evaporator, it takes less ...Low sub cool low superheat 1st stage Trane. I am working with a 4TWA7036A3000 matched with a TAM9A0C36V31DAB, using a 2 stage thermostat. Commercial building with AHU mounted horizontal in the ceiling of the ground floor and heat pump on the roof, with a 50' line set and a 24' rise. Upon start up system was charged in 2nd stage cooling and ...4. When ambient air temp (Outside air temp) is 75-85 degrees the superheat should be 12-15 degrees, if the ambient temperature is 85 degrees or over the superheat should be 8-12 degrees. 5. If superheat is low then flooding the evaporator. Note: Do not adjust charge yet. 6. If superheat is high then starving the evaporator. Note: Do not adjust ...This article explains how subcooling affects the efficiency of your air conditioning system. Read on to learn more about the subcooling process. Financing. 615-746-6390. Emergency Service. ... Perhaps the most common cause of insufficient subcooling is an abnormally low refrigerant charge. Lack of refrigerant usually means that your system ...Another example would be if you have a low indoor load, let's say 70*, you charge to 2* subcool, home owner sets the stat to 78*. As the load increases the tev opens to maintain super heat, now it has no subcool so no liquid to maintain superheat, superheat climbs and performance decreases.What causes low superheat and high subcooling? Because these readings are normal, the low suction pressure is caused by insufficient heat getting to the evaporator rather than low refrigerant. CAUSE #2: A faulty, plugged-in, or undersized metering device is to blame. As refrigerant is added to TXV systems with high superheat, double-check the ...Join Date. Aug 2019. Posts. 106. Post Likes. “Normal” pressures, low subcool. A lot of times when I am checking TXV equipped units I’ll have normal pressures with a very low subcool. For example. 75 indoor. 20 delta t. 85 outdoor. Pressures around 320/130 psi.What causes Low superheat with high subcool. When both low superheat and high subcooling occur simultaneously, it signals a unique condition that can only be attributed to an overall excess of refrigerant in the system. Overcharging the air conditioning system with refrigerant is the primary cause of experiencing both low superheat and high ...Are you planning a special event but worried about the cost of renting a banquet hall? Look no further. In this ultimate guide, we will provide you with all the information you nee...To use our two examples from the previous paragraph, R134a at 0 psig and -5 F has 10 degrees of superheat, and the same refrigerant at the same pressure but at -20 F has 5 degrees of subcooling. These concepts of saturation, superheat, and subcooling are the foundation of all sealed system troubleshooting.How to Calculate Superheat. 1. Obtain suction line temperature: First, measure the temperature of the suction line near the evaporator outlet using a digital thermometer or a clamp-on thermocouple. 2. Determine saturation temperature: Next, read the low side pressure gauge on your HVAC gauges while equipped with corresponding refrigerant …Jun 13, 2017 · For more tips, visit our website, http://www.edgetekhvac.com.To download a copy of our job sheet, visit our online literature library at: http://literature.n... This is important because, in cool mode, a dirty air filter caused low airflow on the evaporator. In those cases, you would typically notice a low suction pressure and a low superheat. In heat mode, a dirty air filter causes low airflow across the condenser. That can cause extremely high head pressure. In heat mode, a dirty outdoor coil can ...Apr 22, 2024 · However, this time you consider the three main causes of low suction pressure and check superheat and subcooling to make the correct diagnosis. CAUSE #1: Insufficient heat getting to the evaporator. This can be caused by low airflow (e.g., dirty filter, slipping belt, undersized or restricted ductwork, dust and dirt buildup on blower wheel) or ... Subcooling is beneficial because it prevents the liquid refrigerant from changing to a gas before it gets to the evaporator. Pressure drops in the liquid piping and vertical risers can reduce the refrigerant pressure to the point where it will boil or "flash" in the liquid line. This change of phase causes the refrigerant to absorb heat before ...Bryan with HVAC School goes over AC pressures, subcooling, and superheat in his troubleshooting mindset presentation from the BTrained HVAC training event in Birmingham, AL. Bryan also talks a bit about his educational photo-sharing app, MechPic. The suction pressure and suction saturation give us an idea of the refrigerant’s …Conversely, if the valve is stuck open, it can lead to low subcooling. Incorrect Refrigerant Type: Using the wrong type of refrigerant can disrupt the system's performance, causing superheat and subcooling issues. Fixing Low Superheat and Low Subcooling. Check Refrigerant Charge: Start by checking the refrigerant charge using a manifold gauge ...Superheat: 51 F Subcool: 8 F Trane R410A system has a design subcool of 10 +/- 3 degrees so my subcooling is within the threshold. I did not see a filter drier on either the suction or discharge lines to take a temperature drop across to see if there is more than a 2 degree difference aka change that out.Oh, and also, the pressures were not low. That and the high subcool makes me think it cannot be low on refrigerant just because the superheat is high. I think the other technician was correct. The condenser was dirty or there was a restriction. Adding refrigerant was not really the answer although it worked. Superheat and Subcooling are technical readings in an HVAC that measure the Freon (refrigerant) reading. Superheat measures the Freon boiling point in gas form while subcooling measures the Freon in liquid form below the evaporation level. To calculate superheat and subcooling measurements, a specific Mathematical chart is used, and the process ... May 28, 2003 · On traditional systems, which use mechanical metering devices such as TXVs or cap tubes, the superheat heating will vary between 8 degrees and 20 degrees. On newer systems that use electronic expansion valves and solid-state controllers, it is possible to see the superheat setting as low as 5 degrees to 10 degrees. Subcooling The last function of the condenser is to subcool the liquid refrigerant. Subcooling is defined as any sensible heat taken away from 100% saturated liquid. Technically, subcooling is defined as the difference between the measured liquid temperature and the liquid saturation temperature at a given pressure.A network storage device is one of the best ways to keep your data backed up, but it can be a little pricey to set up and leaving a computer on all the time sucks a lot of power. I...

Evap would show a higher suction pressure but low superheat due to flooded condition. shophound Okay, but not releevant to my statements. udarrell The reversing valve can be ruled out easily because if it was leaking discharge gas to suction, there would be a greater heat rejection load imposed on the outdoor coil, reducing …. Anyone but you showtimes near showcase cinemas warwick

low subcool low superheat

Subcooling should be 5-18 degrees, with higher values when the equipment has a TXV. Always refer to the manufacturer's specifications for accurate measurements. Troubleshooting Using Superheat and Subcooling Data. Low superheat: Indicates too much refrigerant in the evaporator, likely due to overcharging. Superheat and Subcooling are technical readings in an HVAC that measure the Freon (refrigerant) reading. Superheat measures the Freon boiling point in gas form while subcooling measures the Freon in liquid form below the evaporation level. To calculate superheat and subcooling measurements, a specific Mathematical chart is used, and the process ... Measure Superheat: This involves subtracting the actual suction line temperature found by means of a clamp on thermometer from the saturation temperature on the low pressure gauge and compare that to the design saturation point on the pressure temperature chart for that specific ambient. Your reading should be close.Pharmacology and the Nursing Process 7th Edition • ISBN: 9780323087896 (1 more) Julie S Snyder, Linda Lilley, Shelly CollinsLow Superheat Low Subcooling: Learn To Fix It. Low superheat and low subcooling are the indicators for your evaporator to be low on heat and have a limited refrigerator in its condenser. We will …Steam at 213 degrees F is superheated by 1 degree F. Superheat is then any temperature of a gas above the boiling point for that liquid. When a refrigerant liquid boils at a low temperature of 40 degrees in a cooling coil and then the refrigerant gas increases in temperature, superheat has been added. If this refrigerant changed from a liquid ...Post Likes. Low subcooling results when there is insufficient refrigerant to fill the lower part of the condenser coil. High suction superheat results when there is insufficient refrigerant to fill the evaporator properly. If you have insufficient refrigerant in both places - it is likely that the system is undercharged.Low airflow can be caused by a dirty or clogged air filter or a malfunctioning fan or blower motor, so be sure to investigate those components as the source of insufficient airflow. Low refrigerant charge. As seen in the table in Figure 2, a low refrigerant charge will result in a higher superheat and a lower subcooling and lower evaporator ...Both are out of cooling. and both have high superheat. like suction 20psi -7F, suction line temp 78F, head pressure 190psi, 97F, liquid line temp 72F, out door dry bulb temp 73F, Wet bulb at register indoor 19F, indoor dry bulb temp at register 78F. At the start of the suction.Subcooling is a measurement of temperature DECREASE of a liquid below its saturation (mixed liquid/vapor) temperature at a given pressure. For example, water boils at 212° Fahrenheit at sea level (atmospheric pressure of 14.7 PSIA). If water is 212°F and at atmospheric pressure at sea level, you can be sure it is at saturation, which means it ...With only 2 degrees subcooling you may have liquid flashing or boiling in the liquid line due to pressure drop due to friction and a small liquid lift. Also the split measured at the registers may be considerably lower than the split across the evaporator because of heat gain in the ductwork. Check it out.In this HVAC Training Video I go over the Basic Refrigeration Cycle of a Walk-In Box Refrigeration System along with the Operation. I Explain the Refrigerant...8-12* superheat would be what you want to shoot for. higher the superheat, the more starved the evaporator is. you definitely have to factor in them long linesets. if you can get the superheat down to the margin, roll with it. you will know your overcharged if your superheat falls below the margin.-undercharged-high superheat and low subcooling-lack of subcooling- low sub cooling normal superheat -clogged filter drier-1-2 degree differential. calculating superheat. Temperature evaporator out- Temperature low side, 4-8 F. Calculating subcooling. temperature high side - temperature condenser out 10 F.Superheat basically tells us about the refrigerant on the evaporator side of the system and subcooling the condenser side. If superheat is high, there isn't enough refrigerant in the evaporator coil. If it's low, there is too much. It's the opposite for subcooling. Low means there isn't enough in the condenser and high means there is ....